PTFE pleated filter cartridge


Provides safe, sterile filtration for air and gas applications in pharmaceutical and food & beverage industries.
- Polypropylene components and hydrophobic polytetrafluoroethylene (PTFE) membrane construction allow use in a range of air and gas applications
- Sterilizing-grade meets Bacterial Challenge Test ASTM F838, providing safe, sterile filtration
- All components meet USP Class VI Plastics Test, providing biosafety insurance and global regulatory compliance
- 100% integrity tested before release provides high-quality, sterility assurance
APPLICATIONS
PTFE pleated filter cartridge application
- Sterile filtration for air and gas
- Vent filtration
Specifications
Drawings
Specifications
Retention rating
- Single-layer
- 0.22 µm
Materials
- Media
- Support
- Sleeve, core, top, and end caps
- O-ring
- Sealing technology
- Polytetrafluoroethylene (PTFE)
- Polypropylene
- Polypropylene
- Silicone
- Thermal bonding without adhesives
Filtration area
- ≥0.58 m2 @ 10", ≥0.28 m2 @ 5"
Normal effective filtration area
- Single-layer
- Dual-layer
- 0.6 m2/10" cartridge
- 0.53 m2/10" cartridge
Integrity test (0.22μm)
- Minimum bubble point at 60% isopropanol water, 25°C (77°F)
- Minimum bubble point at 95% ethanol water, 25°C (77°F)
- Water intrusion at 2620 mbar @ 25°C (77°F)
- ≥1155 mbar
- ≥1100 mbar
- ≤1.0 mL/min @ 5"
- ≤1.4 mL/min @ 10"
Maximum operating conditions
- Maximum forward differential pressure
- 4.2 bar @ 25°C (77°F), 2.0 bar @ 80°C (176°F)
Maximum operating conditions
- 20 cycles of steam-in-place (SIP) sterilization or autoclave, 30 min at 127°C (261°F)
Sterilization cycles
- Maintained integrity after 100 cycles of forward steam-in-place (SIP) sterilization at 135°C (275°F) for 30 min, or 50 cycles of reverse SIP sterilization at 127°C (261°F) for 30 min,or 100 cycles of autoclave at 127°C (261°F) for 30 min
Endotoxin releasing
- <0.25 EU/mL according to the test methodology in USP
TOC
- <0.5 mg/L after a water flush of 5 L/10" cartridge
Conductivity
- ≤1.3 µS/cm after water flush of 5 L/10" cartridge
Particle release
- Meets the requirements of WFI set by USP
Non-fiber releasing
- Meets the criteria for a non-fiber releasing filter defined in 21 CFR 210.3(b)(6)
NVR
- After autoclaving and 24-hours in 50% ethanol water with vibration (contact Entegris for details)
Material toxicity
- All components meet the requirements of the USP Reactivity Test for Class VI Plastics
- Filters meet the requirements of USP Biological Reactivity Tests In Vitro Cytotoxicity
Bacterial challenge test
- Passed the bacterial challenge test using Brevundimonas diminuta (ATCC 19146) at a minimum challenge concentration 1x107 CFU/cm2 (0.22 µm) per ASTM F838
Indirect food additive
- Meets the FDA Indirect Food Additive requirements cited in 21 CFR 177-182
Food contact material
- (EU) No. 1935/2004, (EU) No. 10/2011
Quality
- Manufactured in accordance with ISO 9001 and ISO 13485 certified quality management system
Send your process conditions
TAKE IT TO THE NEXT LEVEL.
Process fluid, filtration objectives, pore size rating, contaminant characteristics, operating temperature and pressure, flow rate, connection type, seal material, sterilization requirements, and existing cartridge specifications (if applicable).