PES pleated filter cartridge



Cofilters PES cartridge filters help ensure reliable product processing in pharmaceutical applications.
- Polypropylene components and polyethersulphone (PES) membrane construction allow use in a broad range of applications
- Optimized form factor allows high flow and low pressure drop, lowering cost of ownership
- All components meet USP Class VI Plastics Test and USP Biological Reactivity Test, providing biocompatibility insurance and global regulatory compliance
APPLICATIONS
PES pleated filter cartridge
Pharmaceutical
- Bioburden reduction of LVP/SVP
- Sterile filtration for LVP/SVP/API
- Buffers
- Culture medium
- Intermediates
- Eye drops, antibiotics
Specifications
Drawings
| Length | Code 0 (A) | Code 5 (A) | Code 6 (A) | Code 7 (A) |
|---|---|---|---|---|
| 5" | 148.0 mm (5.8") | – | 150.5 mm (5.9") | – |
| 10" | 273.0 mm (10.7") | 314.0 mm (12.4") | 276.0 mm (10.9") | 316.5 mm (12.5") |
| 20" | 517.5 mm (20.4") | 558.5 mm (22.0") | 520.0 mm (20.5") | 561.0 mm (22.1") |
| 30" | 762.0 mm (30.0") | 803.0 mm (31.6") | 764.5 mm (30.1") | 805.5 mm (31.7") |
| 40" | 1006.5 mm (39.6") | 1047.5 mm (41.2") | 1009.0 mm (39.7") | 1050.0 mm (41.3") |
Performance Data


Specifications
Retention rating
- Single-layer
- Dual-layer
- 0.22, 0.45 µm
- 0.45/0.22 µm
Materials
- Membrane
- Support
- Sleeve, core, top, and end caps
- O-ring
- Sealing technology
- Polyethersulfone (PES)
- Polypropylene
- Polypropylene
- Silicone
- Thermal bonding without adhesives
Normal effective filtration area
- Single-layer
- Dual-layer
- 0.6 m2/10" cartridge
- 0.53 m2/10" cartridge
Integrity test (0.22μm,0.45/0.22μm)
- Minimum bubble point at 25°C (77°F)
- Maximum diffusion flow at 40.6 psi(2800 mbar) at 25°C (77°F)
- ≥50.7 psi (3500 mbar)
- 5" cartridge: ≤15 mL/min
- 10" cartridge ≤30 mL/min
Maximum operating conditions
- Maximum forward differential pressure
- Maximum operating temperature
- 60.9 psi (4.2 bar) @ 25°C (77°F), 29.0 psi (2.0 bar) @ 80°C (176°F)
- 80°C (176°F)
Multiple sterilization cycles
- 20 cycles of steam-in-place (SIP) sterilization or autoclave, 30 min at 127°C (261°F)
Endotoxin releasing
- <0.25 EU/mL as determined by the LAL test
TOC
- <0.5 mg/L after a water flush of 11 L/10" cartridge
Conductivity
- ≤1.3 µS/cm after water flush of 11 L/10" cartridge
Particle release
- Meets the requirements of WFI set by USP
Non-fiber releasing
- Meets the criteria for a non-fiber releasing filter defined in 21 CFR 210.3(b)(6)
Extractables
- Tested according to USP. Report is available upon request
Material toxicity
-
All components meet the requirements of the USP <88> Reactivity Test for Class VI Plastics
Filters meet the requirements of USP <87> Biological Reactivity Tests in Vitro Cytotoxicity
Bacterial challenge test
- Filters with the claim passed the bacterial challenge testing using Brevundimonas diminuta (ATCC 19146) at a minimum challenge concentration 1x107 CFU/cm2 (0.22 µm) per ASTM methodology.
Indirect food additive
- Meets the FDA Indirect Food Additive requirements cited in 21 CFR 177-182
Food contact material
- (EU) No. 1935/2004, (EU) No. 10/2011
Quality
- Manufactured in accordance with ISO 9001 and ISO 13485 certified quality management system
Send your process conditions
TAKE IT TO THE NEXT LEVEL.
Process fluid, filtration objectives, pore size rating, contaminant characteristics, operating temperature and pressure, flow rate, connection type, seal material, sterilization requirements, and existing cartridge specifications (if applicable).